2019年10月31日星期四

Cellulose Extraction Thimble VS Glass Fiber Extraction Thimble

Established in 2010, Hawach is dedicated to providing special applications, advanced laboratory equipment sales, and services. The years’ experience has laid a solid foundation for HAWACH’s position in the sample pretreatment, gas samplers, soil and water samplers, laboratory and life science filtration, etc.
Hawach’s philosophy is to provide customers with high-performance instruments, high-quality customized solutions, from sales to rapid customization services. Hawach has two kinds of extraction thimbles, based on their different materials–cellulose extraction thimbles and glass fiber extraction thimbles.
1. What is cellulose?
Cellulose is a macromolecular polysaccharide composed of glucose and it does not dissolve in water and common organic solvents. Cellulose is the most widely distributed and most abundant polysaccharide in nature, accounting for more than 50% of the carbon content of the plant kingdom. Cotton has a cellulose content close to 100% and is the natural source of the purest cellulose.
Hawach cellulose extraction thimbles feature consistent high porosity which ensures fast flow through and high fitting accuracy for all available extraction systems. It is used in general Soxhlet extraction and indoor dustfall, indoor toxic organic matter (phthalic acid).
What is glass fiber?
As an inorganic non-metallic material, glass fiber features excellent performance, good insulation, heat resistance, good corrosion resistance, and high mechanical strength. It is a good substitute for metal materials.
Glass fiber has become an indispensable raw material for the construction, transportation, electronics, electrical, chemical, metallurgical, environmental protection, national defense and other industries, thanks to the rapid development of the market economy. Glass fiber has received increasing attention, with the wide application in many fields.
The global fiberglass production and consumption countries are mainly developed countries such as the United States, Europe, and Japan, and their per capita glass fiber consumption is relatively high. Europe remains the largest region for fiberglass consumption, accounting for 35% of total global use.

Why QuEChERS Is Getting More And More Popular?

QuEChERS are widely used in sample handling before food safety inspection. And food safety inspection is vitally important to our life and health. Today, here we are going to talk about the QuEChERS rationale and some relating aspects.
Pesticide residue analysis
Pesticide residue analysis is a complex trace analysis technique. The traditional pretreatment methods mainly include soxhlet extraction, oscillatory extraction, liquid-liquid partitioning, column chromatography, and centrifugation. These methods have the disadvantages of single sample extraction, long purification time, the large amount of toxic organic solvent, low sample recovery rate, and large impact on human health and environment, which can not meet the needs of pesticide analysis in modern batch foods.
At the same time, the composition of various foods is complex, which increases the difficulty of analysis and puts forward more stringent requirements for pesticide residue detection technology.
New technologies
At present, new technologies that have been reported or have been widely used include solid-phase extraction SPE, solid-phase microextraction SPME, supercritical fluid extraction SFE, ultrasonic extraction USE, microwave-assisted extraction MAE, rapid solvent extraction ASE, matrix solid-phase dispersion extraction MSPD, gel permeation chromatography GPC, molecularly imprinted synthetic receptor technology MISR, and the like.

Use Instruction Of Bottle-Top Dispenser

Hawach bottle-top dispenser is usually used by being fixed on the sample vials through the screw valve. Due to the tight and stable sealing, the removal process of the sample solutions is in a closed system. It could effectively avoid the occurrence of evaporation, splashing, tipping, etc.
Package and Delivery of Bottle-top Dispenser
Bottle-top dispenser offered by Hawach Scientific formulates a complete delivery process and reliable package. In the transportation process, all products are packed with hard cartons and thick foam for safe delivery.
Once customers choose the appropriate one based on timeline and budget, ordered products will be delivered as soon as possible, because Hawach has got the unique geographical advantages and convenient transport network. Besides, detailed inspection and delivery plan will be submitted to clients before delivery, to guarantee the package meets the requirements, and delivery is safely and quickly.
Specification of Bottle-Top Dispenser
Hawach Scientific bottle-top dispenser is a convenient device to facilitate the removal of a fixed volume of liquid from other storage bottles. And it can perform accurate and highly repetitive liquid separation without wasting reagents.
Details on Hawach Scientific bottle-top dispenser are provided as follows, the maximum pressure resistance is 500mbar, the maximum viscosity resistance is 500mm, the maximum operating temperature is from 10 to 30 degrees Celsius, and the maximum piston lift is 10ml, the volume range is from 0.1 to 99.9 ml.
Performance of Bottle-top Dispenser
Hawach uses high-grade chemically inert materials to ensure the purity of reagents, which is compatible with a wide selection of samples and is autoclavable for diverse applications.

2019年10月29日星期二

Operation Manual Of Syringe Filter

Hawach Scientific Syringe filter is a rapid, reliable and convenient filtration tool commonly used in laboratory. It is of beautiful and light appearance and high cleanliness. It is mainly used for sample pre-filtration, clear removal of particles, liquid and gas and so on. Hawach syringe filter is the preferred method for filtering HPLC and GC small samples. In application, it does not need to change membrane and clean filter, which greatly saves complex and time-consuming preparation work.
Material of Syringe Filter
Hawach syringe filter is divided into three types, each type is made of different materials, but all of them are of high quality and strict manufacture process. The filter material includes nylon (Nylon), polyvinylidene fluoride (PVDF), polytetrafluoroethylene (PTFE), mixed cellulose (MCE), cellulose acetate (CA), glass fiber (Glass Fiber), polypropylene (PP), polyethersulfone (PES) and 100% Borosilicate glass.
Combined with ultrasonic welding and heat fusion technology, Hawach syringe filter provides with extremely low extractable levels, widest range of chemical compatibility, superior temperature, corrosion and pressure resistance, excellent light transmission, soft texture and easy processing structure.
Improvements of Syringe Filter
Hawach always spends great efforts to improve performance of syringe filter, thus the filter membrane is free of damage and defect, and the selected filter membrane meets the filtration requirements. The correctness of filter installation and operation in the process is given high priority, and satisfy the standards provided by the manufacturers.
Additionally, the sealing property of the filter perfect and there is no gap between the filter membrane and the filter. All syringe filter can stand 100% optical integrity test and CE double recognition.

How To Choose A Sample Vial When Doing An Experiment?

When there is a problem with our experimental results, we always think of the sample vial in the end, but it is what we should consider first. When choosing the right vial for your application, you need to make three decisions: the capping pad, the cap, and the vial itself.
1. About the choice of Inner cap pad
PTFE
Recommended for a single injection
Excellent solvent resistance and chemical compatibility
Will not reseal after piercing
Long-term sample storage is not recommended
PTFE/silica gel
Recommended for multiple injections and sample storage
Excellent resealing characteristics
Chemical resistance to PTFE prior to piercing. After piercing, the capping pad will have chemical compatibility with silicone
Working temperature: -40 °C to 200 °C
Pre-cut PTFE/silica gel
Provides good ventilation to prevent vacuum in the sample vial for excellent sample reproducibility
Eliminate clogging of the bottom needle after sampling
Good resealability
Recommended for multiple injections
Operating temperature is the same as PTFE/silica gel

The General Guidelines Of The Flash Column Chromatography

When flash column works, the upper interface generally has a gas/liquid (with a certain pressure) to speed up the sample separation process. It operates at pressures of 50 -200 psi, as compared to HPLC, which operates at 1000s of psi, and UHPLC which operates above 10,000 psi. Flash column is the primary purification technique used in organic synthesis and industrial applications because it is fast (Flash!), it is easy to use and it is versatile. 
The method of the flash column chromatography is to separate the components from the mixture and purify it. In short, fast column chromatography makes samples go through gel-filled columns, and the gels help make the separation. The founders of the fast column chromatography at first wanted to find a method to overcome the shortcomings of long column chromatography, such as time-consuming and low recovery.
The gel used initially for packing columns is silica gel, which is still widely used. People push solvents through silica gel flash columnsby air pressure. And then they add the samples in it and push samples through the columns. The components needed to be collected and purified will appeared during the process of the elution.
Since the silica gel, flash column chromatography is widely used in organic chemistry, the guidelines are important when you try to get better sample quantity results. The flow rate depends on different column length and width, and the properties of the gel as well.

HWVT-0150 Oil-Free Corrosion Resistant Spiral Vacuum Pump

The disposable vacuum filter is an optional alternative to the solvent filter. Generally, it consists of a diaphragm, graduated polystyrene (PS) funnel, and a collection bottle. It is basically used with a diaphragm vacuum pump, which provides pressure differentials for sample filtration.
Advantages
Compared with other solvent filters, the disposable vacuum filter saves lots of trouble of cleaning and sterilizing for the operators, since it is packaged in a sterile and individual way. More importantly, its large filter area allows faster filtration of large amounts of samples. The pre-filtration layer made of the glass fiber membrane increases the filtration rate. Its spacious and well-designed bottle mouth ensures an effective and stable pouring of the sample. Meanwhile, the subsequent sample can be directly stored in the collection bottle.
Application
The disposable vacuum filter is of great use in the biopharmaceutical industry analysis. It could be applied in the separation and purification of large-volume samples. It is ideal for filtering tissue culture fluids, biological fluids, antibodies, etc. Also, it is suitable for the sterile filtration of solutions that cannot be sterilization with high pressures or temperatures. The difficult-to-filter aqueous solution is also quite available to use this disposable vacuum filter.
Equipped with a set of the manual vacuum control valve (control vacuum from 0.1mbar to atmospheric pressure).

2019年10月28日星期一

About The General Classifications Of Filter Cartridge

The filter cartridge has played an important role in the filter. It can be classified into many types, like the common string-wound filter cartridge, folding microporous filter cartridge, and compressed activated carbon filter cartridge, etc.
It is made by textile fiber yarn with excellent filtering performance precisely twined on a porous framework, which can effectively remove particulate impurities and suspended solids of various liquids, and has a high purifying effect on various liquids.
Folding microporous filter cartridge
It adopts polypropylene thermal spray fiber membrane, filter end cap seal and integral structure connection which are made by hot melt bonding. Taking the Nylon polytetrafluoroethylene microporous membrane and other precision filtration devices as filter media have the advantages of large filtration area, small volume, and high precision. Filtration accuracy can range from 0.1μm to 60μm.
Compressed activated carbon filter cartridge
This kind adopts coal adsorption activated carbon and coconut shell activated carbon with high adsorption value as a filter material and is sintered and formed by a food-grade binder. The inside and outside are wrapped with a layer of non-woven fabric to ensure that the carbon core itself will not drop the carbon powder, and the carbon core is equipped with a soft nitrile rubber gasket at both ends to make it packed into the filter cartridge for good sealing.
Service life
In general, the PP filter cartridge needs to be replaced in 3 months, and the activated carbon filter cartridge needs to be replaced in 6 months. As the hollow fiber filter cartridge can not be cleaned, it is generally placed at the back end of PP cotton and activated carbon to degerm. It needs to be replaced in 1-2 years. Ceramic filter cartridges can generally be used for 10-12 months, and high-quality ceramic filter cartridges can be used for 3-5 years or even longer.

Cleaning Methods Of Membrane Filter

The main application of membranes filter is the filtration of air, gases or chemicals. Membrane filters provided by Hawach have excellent chemical compatibility so that they are also used for the filtration of solvents and acids, to which other filter types are not resistant.
Moreover, it is available in pore sizes from 0.1 um to 10 um and multiple diameters, and therefore excellently suited for the particle removal from solvents. Besides, there is no worry about contamination because all of them are made in a cleanroom. Longer lifetime is guaranteed by fresh sterilization and good thermal stability.
Tips for Membranes Filter
There are some tips for type-selection. Nylon membranes filter is fit for filtration of aqueous biological solutions, alcoholic solutions, and non-aqueous HPLC/GC solvents, it is therefore recommended for the chemical industry. Sterile MCE grid membrane filter is not normal mixed cellulose esters membrane, its special color contrast provided by the membrane surface is good for particle detection and bacteria recovery, and the membrane filter provides with a high degree of the internal surface area for adsorption of solvents, so it is also suitable for food and beverage test applications.
After a period of use, the membrane filter will be contaminated or blocked, which will decrease the water permeability and the filtration speed. Therefore, it is necessary to clean the membrane filter in time to prolong its separation performance and the water flux. Here below are the two most common and effective cleaning methods.

Five Classifications Of HPLC Column

Used in analytical chemistry, a high performance liquid chromatography(HPLC) column is the column that can separate out components from the liquid sample. when liquid samples pass through the HPLC column, depending on how they interact with an adsorbent material packed inside the column, analytes elute at different times. For the highest pressure resistance, HPLC columns are usually constructed of stainless steel.
The Hawach HPLC column can not only meet our worldwide customers’needs of fast HPLC separation, but the traditional methods within the pharmaceutical, environmental, clinical, and food industries as well.
The particle platforms which make up the Hawach HPLC columns are monolithic silica, polymeric, monodisperse silica, ultra-pure silica, and zirconia. With the whole set the different products, you can always find the right ones for your application.
Hawach has a tradition of making innovative HPLC Columns with high column efficiency, excellent shape peaks and low pressure for a longer lifetime. And you can find Hawach C18 Universal HPLC column doing the same good performance as Waters, Agilent, and GL Science.
High performance liquid chromatography (HPLC) columns can be roughly divided into five categories.
1.High performance reversed-phase liquid chromatography column
It is extremely widely used in drug metabolism and kinetics, life sciences, medical health, bioanalytical testing, drug, and stimulant testing, food safety analysis, environmental analysis, military, homeland security, etc. It is also one of the most important separations and purification technologies.
2.High efficiency normal-phase liquid chromatography column
It is the earliest chromatographic mode. Until now, further purification through silica gel column after synthesis is still an important part of the daily work of organic chemists. In theory, almost all organic compounds dissolved in n-hexane, ethyl acetate or isopropanol can be analyzed by high performance normal phase liquid chromatography.

2019年10月27日星期日

About The Specifications Of Hawach SPE Cartridges

About Hawach
Hawach focuses on scientific instrumentation, manufactures high-quality instruments, and interprets perfect service. Hawach is committed to the research of safe nutrition and scientific analytical instruments and analytical methods for chemical, food, and medicine, providing instruments and comprehensive solutions for scientific and technological workers.
SPE cartridges
With the improvement of analysis level, in order to meet the requirements of sample pretreatment, SPE technology is obviously superior to traditional liquid-liquid extraction technology: convenient environmental protection, good reproducibility, time, labor and solvent saving, which has been widely used in organic synthesis, biology chemical, environmental, pharmacological, food, pharmaceutical, public inspection, import and export testing in all areas.
The various specifications of SPE cartridges provided by HAWACH are stable and reliable, suitable for different volume sample processing, and different specifications for easy method screening. SPE cartridges can also be processed according to customer needs.
Structure of SPE Cartridge
Hawach SPE cartridge is composed of several parts, including cartridge pipe, screen pipe, absorber, adapter, sample storage device and other supporting devices. Thereof syringe-shaped column pipe is a carrier of absorbents, made of learn grade polypropylene and provided with standardized dimensions or sizes, can be used in a multi-tube vacuum device. The screen pipe acts as a fixed absorbent and filter solution. The absorber is substances that play a role in separation. The adapter is used to connect the column pipe and column pipe, column pipe, and sample storage device.

Three Skills When Using Pipette

A pipette is an indispensable tool for the experimental operation in the laboratory. It is important to reduce the experimental error to the minimum and improve the repeatability to best.
Factors Affecting The Accuracy
The first thing should be noticed is the accuracy of the pipette during the experimental process. There are mainly three factors that would affect its accuracy in varying degrees. The first common factor is temperature. The air will be expanded when its temperature is higher than the room temperature, which would cause the occurrence of the error when inhaling the cold solution.
The second factor is airtightness, which is caused by the long-term wear of the internal cylinders and the joint between the tip and the pipette body.
The third factor is the volatilization of reagent. When drawing the high-volatility reagent to the pipette, the steam will enter the tip and the internal pressure will be increased.
Consequently, the pressure will be higher when the sample is pressed out, which causes an error to occur. The error could be reduced by repeatedly pumping the pipette 4-5 times.

The Necessity Of Adopting QuEChERS Method

Pre-treatment is the longest and most labor-intensive part of food testing. The quality of pre-treatment determines the accuracy and precision of the analysis. QuEChERS method is a kind of high-precision sample pretreatment technology because it is quick, easy, cheap, effective, rugged and safe. It uses the adsorbent filler to interact with impurities in the matrix to adsorb impurities to achieve impurity removal.
Main steps
The main step of the method is to extract the sample with acetonitrile containing 1% acetic acid, and then add anhydrous magnesium sulfate and sodium acetate to oscillate it to stratify, followed by dispersion solid-phase extraction, that is, the extract is transferred to PSA-containing adsorption.
In a centrifuge tube of magnesium sulfate, centrifuge with a Teflon-coated centrifuge tube, centrifuge the solution to an autosampler for GC/MS or LC/MS and analyze and evaluate its stability and reliability. At the same time, the method can be appropriately adjusted according to the type of analytical instrument available, the limit of detection, the range of the target pesticide, and the difference in the medium used.
Pesticide residues
Pesticide residues are a general term for all derivatives of pesticides and their toxicologically significant impurities, metabolic conversion products, and reactants that remain in organisms, agricultural products, and the environment due to the application of pesticides. The composition of agricultural products and food samples is complex.
The pesticide residue content is extremely low, generally in ppm and ppb, and there are also the influences of pesticide homologs, isomers, degradation products, metabolites, and conjugates. To remove the target simultaneous impurities, reduce chromatographic interference peaks, and avoid contamination of samples by detectors and columns, pretreatment is very important, accounting for about 70% of the workload.

2019年10月24日星期四

Two Major Uses Of Extraction Thimble

Extraction thimble provided by Hawach Scientific is of good filtration performance, which is characterized in high chemical purity, good liquid absorption and perfect retention rate. Hawach is available in many kinds and wide applications for extraction thimble, especially for glass fiber type and cellulose type of extraction thimble.
Both of them are excellent in consist of wall thickness, extraordinary mechanical strength and retention ability. Additionally, both of them provide with uniform high porosity which guarantees the fast flow-through the operation.
Summary of Extraction Thimble
Extraction thimbles available by Hawach Scientific are of a variety of dimensions to fit most extraction units. Hawach extraction thimble is either manufactured with high purity borosilicate glass fibers or high alpha cellulose, which is commonly used in Soxhlet extractors for safe and efficient solid and semi-solid material extraction.
The smooth interior surface and consistent wall thickness are easy to clean and maintenance. All products are manufactured in a clean environment to avoid contamination or pollution from the source. Purify and accuracy of analytical results from the reliable and strict control systems and production lines. And the high fitting accuracy if fit for all Hawach’s extraction system.
Usage
The extraction thimble is mainly used to place the substance to be extracted in a container of the glass below, and then the solution is repeatedly soaked to extract the desired components from the material (for example, extracting pesticide residues from the pepper), the experimental procedure is called Soxhlet extraction.

The Storage And Repair Of Bottle-Top Dispenser

Hawach bottle-top dispenser uses high grade chemically inert materials throughout the whole manufactured process. The dispenser can be screwed directly onto reagent bottles with matched screw threads, and other bottle types can be connected with the provided adapter.
Replaceable filling and discharge valves supply quick and convenient servicing and maintenance. And discharge tube is slotted to guarantee proper orientation upon replacement and maintenance. What’s more, the self-sealing multi-layer piston has simplified whole maintenance and management.
Features
The bottle-top dispenser could be suitable for any reagent vials in the laboratory, which is provided with all optional sizes. It is designed with a precise scale and volume setting.
Moreover, it is qualified with strong chemical resistance, which could be applied in the experiments engaged with strong solutions and can be sterilized by high temperatures. Generally, it could cover a range of 0.5-50ml capacity. Its convenient design ensures simple and economical cleaning and maintenance for itself.
The unique design of the bottle-top dispenser
Hawach bottle-top dispenser is of built-in features, which comprises a safe system with closure cap and discharge tube to avoid potential spilling or dispensing. The slotted discharge tube guarantees correct installation and safe operation in practical applications. The inner glass piston is enclosed in an inert polypropylene sleeve so as to avoid accidental damage and permit smooth operation.
What’s more, flexible dispensing options can suit different application workflows. Accessories changing process is easy and fast such as tube discharging and filling procedures. And fixed and flexible discharge tubes are available in diverse sizes to meet all kinds of meets.

2019年10月23日星期三

Difference In Hawach Quantitative And Qualitative Filter Papers

Filter paper is used to separate solids from fluids by interposing a porous media through which only the fluid can pass. We can find two different types of filter papers: Quantitative and Qualitative. And for better results, you should learn how to choose the best type for your applications.
The filter paper can remove harmful dust, smoke, poisons, etc. from the gas, and separate the impurity particles from the liquid; it can also block bacteria, microorganisms and the like. It can also be divided into air filter paper and liquid filter paper from the use.
Materials and types
The filter paper is made of one or more of inorganic fiber, plant fiber, and synthetic fiber, adding the appropriate amount of chemical auxiliaries and fillers, and is made by papermaking technology. It is a kind of filter media and s a scientific tool that is porous and has good filtration performance.
Currently, filter paper has been widely used in various fields. However, because of the different types of fibers constituting the filter paper, the performance and use of the filter paper are different.
There are ordinary filter papers for general occasions, glass fiber filter papers for high temperature, and polypropylene filter papers for ultra-clean and so on. Based on the usages, it can be divided into paint filter paper, paint mist filter paper and grinder filter paper. In the lad, there are quantitative analysis filter paper, qualitative analysis filter paper, and chromatographic qualitative analysis filter paper.

Three Kinds Of SPE Cartridges

Solid phase extraction, as we called it as SPE, is widely used for the pretreatment when the sample is analyzed. With SPE used for separation, the solution will be generally left behind by gravity or with a vacuum device to speed up the separation, and many of the problems associated with liquid/liquid extraction can be avoided, such as incomplete phase separations, less-than-quantitative recoveries.
The scientists in the lab also can save lots of expensive, breakable specialty glassware, and they don’t need to dispose of large quantities of organic solvents.
SPE is an advance way to prepare liquid samples and extract semivolatile or nonvolatile analytes. The scientists often use it with solids that are pre-extracted into solvents as well. Compared with the liquid/liquid extraction, SPE is more efficient and easy to perform.
Available in a wide variety of chemistry, adsorbents, and sizes, Hawach SPE cartridges are excellent tools for sample extracting, concentrating and cleanup. With the consist of a medical PP empty tube, a medical PE sieve plate, and a fixed adsorbent, you can find Hawach SPE Cartridges in different types of silica gel, polymer, adsorption, and the special cartridge according to matrix type.
SPE is a physical extraction process consisting of a liquid phase and a solid phase. During the extraction process, the adsorption of the solid relative analyte is greater than that of the sample base.
When the sample passes through the solid phase cartridge, the analyte is adsorbed on the surface of the solid filler, and the other sample components pass through the cartridge analyte and can be eluted with a suitable solvent to achieve separation and purification.

Attractive Points And Consideration Factors Of Syringe Filter

Syringe filter could be divided into a disposable and multiple-time filtering tool based on its usage frequency. In terms of the different filter membranes used, there are five kinds of syringe filters mainly used for the lab experiments, including Nylon, PVDF, PTFE, CA, Glass Fiber, PP, PES syringe filter. Especially, the PVDF, PTFE, Nylon and PES filter would be specifically introduced as below.
Attractive Points
Hawach syringe filter is a cost-effective way to improve the quality of HPLC analysis, and suitable for a multiple of other applications. Precisely designed structure ensures the fluency of the filtration, improves consistency, extends column life and reduces maintenance. By removing particles before the sample enters the column, Hawach syringe filter allows unimpeded flow.
Besides, reasonable inner space minimizes the hole-up volume, so that the waste is greatly reduced. Housing material is medical grade polypropylene, which gives it better chemical compatibility and excellent chemical stability. Edge is matched with screws which makes operator more convenient to use. Standard female and male lure lock provides better sealing effect and greater strength to the filter housing without leakage and bursting.
Consideration Factors
Hawach Scientific is noted for the most advanced equipment, the strict testing process, and the best service. Hawach research team keeps on investing and testing syringe filters for lab industry and pursuing perfection, and makes endeavor to offer the best syringe filter to customers.
Avoid the introduction of other impurities in the filtration process, especially the shell materials or shed particles from the filter membrane, if it is used to treat chromatographic samples. Different types of syringe filters are suitable for different properties of samples due to different materials.

2019年10月22日星期二

To Know More About HAWACH Sample Vials Production

HAWACH sample vials are manufactured with precise design, professional technology, and strict technical specifications. We also perform rigorous testing of dimensions such as polishing, OD and length to ensure that each vial is exactly matched to the autosampler jaw and sample system.
Our sample vials are made of bismuth quality borosilicate glass and meet ASTMTYPEI ClassA and USP TYPE I standards. Moreover, its whole production line is under a high standard of quality control.
HAWACH specializes in providing laboratories and industrial testing instruments from basic to specialized whose professional technical support and after-sales service have won a good reputation. Over the years, HAWACH has been committed to serving analytical fields, providing high-quality laboratory consumables, laboratory reagents and laboratory instruments.
Sample vials production
All products are produced under strict cleanliness standards, in accordance with the high hygienic conditions of the pharmaceutical standards, with high-quality raw materials under very mature production conditions.
The HAWACH sample vials are made from a grade 1 hydrolyzed glass material through a 600-degree annealing process. This product is used for long-term storage of aqueous solutions. The photodetector on the glass production equipment then detects whether the bottle produced meets the standard.

Key Technical Parameters And Highlights Of HAWACH Flash Column

Used to purify organic compounds, the Flash column is a fast and inexpensive technology. It was originally discovered by W.C. Stills of Columbia University in 1978 and was published in the Journal of Organic Chemistry in 1978.
HAWACH products have been widely used in biopharmaceuticals, life sciences, education, government agencies, and health industries, etc. Since its inception, HAWACH has served more than numerous customers and provides OEM and customized services to dozens of well-known brands around the world. Its product lines cover sample preparation, filtration and sample collection and so on. Today’s focus will be on the flash column.
Principle
Flash column utilizes a plastic column filled with some form of solid fill material, typically silica gel, and the separated sample is placed on top of the solid fill material. The column is a gradient solvent, which allows the sample to fill the column and be separated by means of pressure. Flash column initially uses air pressure, but today pumps are used to accelerate separation. This technique is known as low-pressure chromatography and can separate samples from milligrams to tens or hundreds of grams.
This technique is particularly advantageous because it allows for faster flow rates of the solvent, as opposed to simple gravity flow. Special considerations for flash chromatography include the usage of finer particle size for the stationary phase (such as silica gel).
Classification of HAWACH flash column
There are three series of the flash column at HAWACH, namely
StarFlash series: Only silica gel columns included which are divided into standard and advanced grades. The advanced silica gels are of higher purity and better quality.
PureFlash series: Corresponding to silica gel construction and phase column, C18 (spherical inlet and irregular domestic), C4, C8, NH2, CN, HILIC, alumina and so on. All are imported fillers for the high-end market.

The Basics You Should Know About The Capsule Filter

Hawach is a tech-driven company that commits to research and development of innovative lab products to improve experiment conditions and results. It has developed a full product range composed of core materials with unique performance capabilities.
The filter capsule, also known as the integral filter, could ensure there is no contaminant in the sample. The PP filter capsule uses a laminated filter membrane with a large filtration surface area, which is suitable for the filtration of large volume solutions. It has different available bore sizes provided.
Classification
Hawach capsule filter uses different filter media depending on the characteristics of the filter object. The following are the commonly used series:
1. It adopts hydrophobic polytetrafluoroethylene (PTFE) filter membrane, which is suitable for solvent and corrosive solution filtration, air and gas vent filtration.
2. It uses hydrophilic polypropylene (PP) filter membrane, suitable for reverse osmosis and ultrafiltration pre-filter, ink filtration, and also for filtering aqueous and solvent samples.
3. It can be made of nylon membrane, which has the characteristics of a fast flow rate and low level of extractable. Pre-filter media with glass fiber can be used to extend the service life of nylon membranes, suitable for filtration of larger volume samples and difficult-to-filter samples.
Others include lithography capsule filter, ink capsule filter, fuel capsule filter, developer capsule filter, and toothpaste additive capsule filter.

2019年10月21日星期一

Use Precautions Of Membrane Filter

Hawach membrane filter is one of the most commonly used lab tools in many fields, such as scientific research, food testing, chemical industry, nanotechnology, energy, and environmental protection. During the use, the following aspects need the operators to pay great attention to.
Performance of Nylon Membrane Filter
Hawach Nylon membrane filter is internally designed with an inert, internal polyester support web, which gives it added dimensional strength and stability to prevent cracking, curling and breaking.
This added strength and durability is advantageous compared with traditional types during usage because it involves aggressive handling or automated equipment. As a naturally hydrophilic membrane, Hawach Nylon membrane filter does not require wetting agents that can interfere with biological processes. In addition, its high surface area and high flow rate successfully immobilize antigens, antibodies and other proteins.
Humanization of Membrane Filter
The membrane filter provided by Hawach Scientific is customized to meet customers’ application and size requirements. Sales policy is flexible, and small order is acceptable. All customization is convenient and cost-effective because all products are manufactured on-site in Hawach facilities.
For additional information, for all customers OEM specific applications, Hawach Scientific has the product breadth and flexibility to meet customer’s needs, as well as the quality standards to help ensure customers’ success. Contact Hawach to discuss application requirements and order products.
According to the adsorption mechanism and the porosity character of the membrane and supporting layer, we can explain why the membrane filter cannot be easily blocked with clean water.
On the contrary, the wastewater with oil will lead to blocking. As for common suspended solid, particles that are larger than the membrane pore will be filtered out of the surface of the membrane.

Diol HPLC Column And C30 HPLC Column

Hawach HPLC column has become one of the most important laboratory tools for separation and purification technology, whose main function is to separate each substance in the sample. HPLC technology has been widely used in the fields of chemistry, medicine, food safety, etc. Generally, there are mainly three types of HPLC columns satisfying customers’ various requirements.
By employing the high-purity silica gel as the matrix, the Diol HPLC column uses unique bonding technology to make itself more stable and durable in aqueous media. The detailed information of the column would be described as follows.
Lutein and vitamin E are common nutrient enhancers in foods. The analytical methods for these two types of substances are clearly defined in the food nutrition enhancer use standards. The separation of isomers is also specifically illustrated. The C30 HPLC column is a specially designed column for the separation of carotenoid isomers.
Features
First of all, the Diol HPLC column has higher selectivity than the normal-phase separated silica gel, since the hydrophilicity of the diol group is weaker than the one of pure silica gel. The polarity of its stationary phase is slightly less than the unbonded silica gel, which provides moderate positive phase retention and excellent selectivity. Besides, its high-performance silica gel and special bonding technology could stabilize the diol bonded phase in the aqueous medium without loss of column service life. Also, it has high inertness and durability.

2019年10月20日星期日

Filtstar Series PES Syringe Filters

Hawach FILTSTAR PES series syringe filters are the hydrophilic and low affinity for proteins and extractable, which results in high throughputs when these small filter devices are used to sterilize or clarify viscous proteinaceous solutions.

Features of PES Syringe Filters

Hydrophilic Syringe Filter
•Wide pH range (1-14)
•Female Luer-Lock inlet and male Luer slip outlet

Advantages of PES Syringe Filters

•Human hands never touch the filter during assembly
•100% integrity tested, individually packaged, and sterilized
•Manufactured in a controlled environment using an automated process
•Include a Certificate of Quality

Applications of PES Syringe Filters

•Sterilize biological fluids, serum or tissue culture media additives
•Sample preparation of aqueous solutions
•High throughput, low binding filter
•Units for sterile aqueous filtrations
•Filter probe and hybridization solutions to reduce backgrounds
•Sample preparation of protein-based
•HPLC solutions
•High throughputs when sterilizing or clarifying even the most viscous proteinaceous solutions
ICP-MS on metal ion extractable test of PES syringe filter(Filstar series)
Experiment object
To verify Hawach Scientific Co., Ltd PES syringe filter can use in ICP-MS on metal ion test field, and quantitative test the amount of extractable ion.
Experiment process
Hawach Scientific Co., Ltd PES Syringe Filter(25mm 0.22) is filtered by 3ml ultra-pure water, the first 1ml discard, collect the first 2ml filter water and go on tested by ICP-MS of several ion species. Each sample was repeated for 3 times.
Experiment result
onBiPbTlHgBaSbSn
Amount< 0.01 ppb< 0.2 ppb< 0.02 ppb< 0.02 ppb< 0.1 ppb< 0.1 ppb< 0.1 ppb
IonCdAsSeZnCuNiFe
Amount< 0.05 ppb< 0.05 ppb< 0.05 ppb< 0.1 ppb< 0.2 ppb< 0.2 ppb< 0.5 ppb
IonCoMnCrAlCaKNa
Amount< 0.2 ppb< 0.2 ppb< 0.2 ppb< 0.5 ppb< 5 ppb< 5 ppb< 10 ppb
Technical Data
Filter MediaPES
Diameter4mm13mm25mm33mm50mm
HousingMedical PPMedical PPMedical PPMedical PPMedical PP
Pore Size0.1μm, 0.22μm, 0.45μm, 0.65μm, 1.0μm, 3.0μm, 5.0μm
Filtration Area0.2cm21.3cm24.9cm28.5cm219.8cm2
Maximum Pressure5.2bar5.2bar5.2bar5.2bar5.2bar
Process Volume2mL10mL100mL200mL5000mL
Pre-filter1um GF or PP1um GF or PP1um GF or PP1um GF or PP1um GF or PP
Hold-up Volume< 10μL< 50μL< 100μL< 200μL< 350μL
InletFemale Luer LockFemale Luer LockFemale Luer LockFemale Luer LockStepped barb
OutletMale luer slipMale luer slipMale luer slipMale luer slipStepped barb
Operate temperature60℃

Instruction Drawing
syringe filters analysis chart
Ordering Information
Item CodePore Size(μm)Diameter(mm)SterilePre-filterQuantity/pk
SLPES0410N0.104NoNo100pcs
SLPES0422N0.224NoNo100pcs
SLPES0445N0.454NoNo100pcs
SLPES0465N0.654NoNo100pcs
SLPES04100N1.04NoNo100pcs
SLPES0410NP0.104NoPP100pcs
SLPES0422NP0.224NoPP100pcs
SLPES0445NP0.454NoPP100pcs
SLPES0465NP0.654NoPP100pcs
SLPES04100NP1.04NoPP100pcs
SLPES0410NG0.104NoGF100pcs
SLPES0422NG0.224NoGF100pcs
SLPES0445NG0.454NoGF100pcs
SLPES0465NG0.654NoGF100pcs
SLPES04100NG1.04NoGF100pcs
SLPES1310N0.1013NoNo100pcs
SLPES1322N0.2213NoNo100pcs
SLPES1345N0.4513NoNo100pcs
SLPES1365N0.6513NoNo100pcs
SLPES13100N1.013NoNo100pcs
SLPES1310NP0.1013NoPP100pcs
SLPES1322NP0.2213NoPP100pcs
SLPES1345NP0.4513NoPP100pcs
SLPES1365NP0.6513NoPP100pcs
SLPES13100NP1.013NoPP100pcs
SLPES1310NG0.1013NoGF100pcs
SLPES1322NG0.2213NoGF100pcs
SLPES1345NG0.4513NoGF100pcs
SLPES1365NG0.6513NoGF100pcs
SLPES13100NG1.013NoGF100pcs
SLPES2510N0.1025NoNo100pcs
SLPES2522N0.2225NoNo100pcs
SLPES2545N0.4525NoNo100pcs
SLPES2565N0.6525NoNo100pcs
SLPES25100N1.025NoNo100pcs
SLPES2510NP0.1025NoPP100pcs
SLPES2522NP0.2225NoPP100pcs
SLPES2545NP0.4525NoPP100pcs
SLPES2565NP0.6525NoPP100pcs
SLPES25100NP1.025NoPP100pcs
SLPES2510NG0.1025NoGF100pcs
SLPES2522NG0.2225NoGF100pcs
SLPES2545NG0.4525NoGF100pcs
SLPES2565NG0.6525NoGF100pcs
SLPES25100NG1.025NoGF100pcs
SLPES3310N0.1033NoNo50pcs
SLPES3322N0.2233NoNo50pcs
SLPES3345N0.4533NoNo50pcs
SLPES3365N0.6533NoNo50pcs
SLPES33100N1.033NoNo50pcs
SLPES3310NP0.1033NoPP50pcs
SLPES3322NP0.2233NoPP50pcs
SLPES3345NP0.4533NoPP50pcs
SLPES3365NP0.6533NoPP50pcs
SLPES33100NP1.033NoPP50pcs
SLPES3310NG0.1033NoGF50pcs
SLPES3322NG0.2233NoGF50pcs
SLPES3345NG0.4533NoGF50pcs
SLPES3365NG0.6533NoGF50pcs
SLPES33100NG1.033NoGF50pcs
SLPES5010N0.1050NoNo25pcs
SLPES5022N0.2250NoNo25pcs
SLPES5045N0.4550NoNo25pcs
SLPES5065N0.6550NoNo25pcs
SLPES50100N1.050NoNo25pcs
SLPES5010NP0.1050NoPP25pcs
SLPES5022NP0.2250NoPP25pcs
SLPES5045NP0.4550NoPP25pcs
SLPES5065NP0.6550NoPP25pcs
SLPES50100NP1.050NoPP25pcs
SLPES5010NG0.1050NoGF25pcs
SLPES5022NG0.2250NoGF25pcs
SLPES5045NG0.4550NoGF25pcs
SLPES5065NG0.6550NoGF25pcs
SLPES50100NG1.050NoGF25pcs