The quality of HAWACH SPE cartridge is stable and reliable, is ideal for different volume sample processing. SPE cartridge can be customized according to customer’s requirements. It is easy to use, fast and efficient, with multiple stationary phase options. Moreover, for routine analysis, they are attractively priced for high-throughput laboratories, which is solvent saving and has high sample recovery.
Wide applications
HAWACH SPE cartridges can be applied to many different industries, like
Separation and analysis of compounds in organic synthesis
Surfactants and other industrial fields
Environmental testing of water samples (drinking water, wastewater)
Detection of pesticide residues in vegetables
Analysis of seasoning aroma in food and beverage
Detection of gaseous sulfides and drug residual solvents (VOCs)
Forensic analysis of fire or explosive samples
Toxic analysis; analysis of drugs and drugs in blood and urine fluids, etc.
HAWACH SPE cartridges can be applied to many different industries, like
Separation and analysis of compounds in organic synthesis
Surfactants and other industrial fields
Environmental testing of water samples (drinking water, wastewater)
Detection of pesticide residues in vegetables
Analysis of seasoning aroma in food and beverage
Detection of gaseous sulfides and drug residual solvents (VOCs)
Forensic analysis of fire or explosive samples
Toxic analysis; analysis of drugs and drugs in blood and urine fluids, etc.
Customer service
Customer service is our highest priority. A person, not a phone system, will answer your call. All inquiries are responded to promptly. We offer a warranty on all parts and labor. If there is anything wrong with the cartridges or any problem with the experiment, we are here to solve it.
Customer service is our highest priority. A person, not a phone system, will answer your call. All inquiries are responded to promptly. We offer a warranty on all parts and labor. If there is anything wrong with the cartridges or any problem with the experiment, we are here to solve it.
Reverse phase extraction column
Extract non-polar samples from polar matrices
1. Activation: rinse the extraction column with 3-5 ml of methanol; rinse it with 3-5 ml of deionized water (or buffer) and keep it moist.
2. Loading: The sample is evenly passed through the extraction column at a suitable flow rate.
3. Cleaning: The extraction column of the adsorbed sample is eluted with 5ml of the solvent of appropriate polarity (pure water, buffer, water/organic solvent mixture are commonly used).
4. Elution: The sample to be tested is eluted in batches with 1-5ml of non-polar solvent to the collection container.
Extract non-polar samples from polar matrices
1. Activation: rinse the extraction column with 3-5 ml of methanol; rinse it with 3-5 ml of deionized water (or buffer) and keep it moist.
2. Loading: The sample is evenly passed through the extraction column at a suitable flow rate.
3. Cleaning: The extraction column of the adsorbed sample is eluted with 5ml of the solvent of appropriate polarity (pure water, buffer, water/organic solvent mixture are commonly used).
4. Elution: The sample to be tested is eluted in batches with 1-5ml of non-polar solvent to the collection container.